The Allen-Bradley 1746-P2 is an SLC 500 modular power supply. It comes with an input voltage of 85-132 or 170-265V AC at 47-63 Hz. Its internal current capacity at 5V is 5 A and it is 0.96 A at 24V. This power supply also comes with a maximum user-supplied overcurrent protection of 15 A and a maximum inrush current of 20 A. It has a 180 VA typical line power requirement and an input terminal and backplane isolation of 1800V AC RMS for 1 s. User-power current capacity at 24V DC is 200 mA and the user-power voltage range of the power supply, also at 24V DC, is 18-30V DC.

It has a maximum of two AWG wires per terminal. Fuse protection is present with the 1746-P2 power supply but it is limited to guarding against fire hazards due to short-circuit conditions. It comes with an open-type enclosure and can only be installed in a 1746 chassis. The entire power supply measures 5.5 x 2.9 x 5.7 inches and weighs 1.1 kg or 2.5 lbs. Its operating temperature is from 0-60 Deg. Celsius.

This power supply module has a jumper terminal that is used to set the input voltage to be applied to the device.

When undervoltage operation happens, the 1746-P2 power supply will continue to power up the SLC 500 controllers for a short period. When the power supply continues to receive input voltage that is lower than the recommended operating range for a period of time longer than the CPU hold-up time, the controllers will turn off. It will only resume operations automatically when the power supply receives the recommended operating input voltage.

For overcurrent conditions, the 1746-P2 Series A and B will undergo a power supply shutdown and CPU fault. The recovery procedure is to reload the user program. For the 1746-P2 Series C, it will have a 24V DC user shutdown but the CPU continues its operation and the recovery procedure is to correct the overcurrent condition.

The 1746-P2 is a Power supply module primarily designed for use with the SLC 500 automation system platform. This power supply is installed in the leftmost of the SLC chassis.

The installation location of this power supply is not included in the slot count. The slot counting starts with Slot Zero (0) which is reserved for the Programmable Logic Controller’s (PLC) processor or SLC 500 communication adapter.



Product Parameter


Model Number: 1746-P2

Origin:USA


A-B series of products


1326AB-B720F-M2L1732E-IB16M12DR
1336-WB1101734-IE4C
1420-V2-ENT1738-AENT SER.B
1440-DYN02-01RJ1746-NI16I